ANS is committed to advancing, fostering, and promoting the development and application of nuclear sciences and technologies to benefit society.
Explore the many uses for nuclear science and its impact on energy, the environment, healthcare, food, and more.
Explore membership for yourself or for your organization.
Conference Spotlight
2025 ANS Winter Conference & Expo
November 9–12, 2025
Washington, DC|Washington Hilton
Standards Program
The Standards Committee is responsible for the development and maintenance of voluntary consensus standards that address the design, analysis, and operation of components, systems, and facilities related to the application of nuclear science and technology. Find out What’s New, check out the Standards Store, or Get Involved today!
Latest Magazine Issues
Sep 2025
Jan 2025
Latest Journal Issues
Nuclear Science and Engineering
October 2025
Nuclear Technology
September 2025
Fusion Science and Technology
Latest News
University of Nebraska–Lincoln: Home of ANS’s newest student section
Following official confirmation in June at the American Nuclear Society’s 2025 Annual Conference, the University of Nebraska–Lincoln has kicked off its first year as the newest ANS student section.
M. Angelone, P. Batistoni, M. Pillon, V. Rado, A. Esposito
Nuclear Science and Engineering | Volume 126 | Number 2 | June 1997 | Pages 176-186
Technical Paper | doi.org/10.13182/NSE97-A24471
Articles are hosted by Taylor and Francis Online.
TLD-300 (CaF2:Tm) dosimeters were used to measure the absorbed dose in an experimental assembly simulating the shield and the superconducting coils of a fusion reactor irradiated by 14-MeV neutrons. The shield was formed by plates of Type 316 stainless steel and by a water-equivalent material (Perspex), while a second block made of Type 316 stainless steel and copper plates simulated the superconducting coils of the tokamak. Since the TLD-300 shows two main peaks, one of which is more sensitive to neutrons, the neutron and gamma doses were separated using the two-peak method. The resulting absorbed neutron dose was 30% of the total in positions close to the neutron source, while its contribution was negligible (< 7%) in the superconducting coils. The total dose level to be studied ranged from a few tens of micrograys to 10 Gy. Because the latter value was expected to be out of the linear response range for the TLD-300, the supralinear effects for the TLD-300 were studied as well as its sensitivity to determine the possibility of its use for doses as low as 10 μGy. Since the detector background can introduce an uncertainty of less than ±10%, the measurement of very low doses was performed with a total error lower than ±15%.