The description of algorithm to design in-pipe experimental ampoule devices (IPAD) is presented here, including description of IPAD design for irradiation tests of highly enriched lithium ceramics at WWR-K reactor. The description of the system for registration of tritium release from ceramics during irradiation is presented as well. Typical curve of tritium release from the IPAD during irradiation under various temperatures of the samples is shown here.