ANS is committed to advancing, fostering, and promoting the development and application of nuclear sciences and technologies to benefit society.
Explore the many uses for nuclear science and its impact on energy, the environment, healthcare, food, and more.
Explore membership for yourself or for your organization.
Conference Spotlight
2025 ANS Winter Conference & Expo
November 9–12, 2025
Washington, DC|Washington Hilton
Standards Program
The Standards Committee is responsible for the development and maintenance of voluntary consensus standards that address the design, analysis, and operation of components, systems, and facilities related to the application of nuclear science and technology. Find out What’s New, check out the Standards Store, or Get Involved today!
Latest Magazine Issues
Sep 2025
Jan 2025
Latest Journal Issues
Nuclear Science and Engineering
October 2025
Nuclear Technology
September 2025
Fusion Science and Technology
Latest News
NNSA awards BWXT $1.5B defense fuels contract
The Department of Energy’s National Nuclear Security Administration has awarded BWX Technologies a contract valued at $1.5 billion to build a Domestic Uranium Enrichment Centrifuge Experiment (DUECE) pilot plant in Tennessee in support of the administration’s efforts to build out a domestic supply of unobligated enriched uranium for defense-related nuclear fuel.
G. Bertschinger, O. Marchuk, TEXTOR Team
Fusion Science and Technology | Volume 47 | Number 2 | February 2005 | Pages 253-259
Technical Paper | TEXTOR: Diagnostics | doi.org/10.13182/FST05-A704
Articles are hosted by Taylor and Francis Online.
At TEXTOR, an X-ray spectrometer in a Johann mount is utilized to measure the X-ray spectra of He-like elements with intermediate Z. Up to now, the spectra of He-like argon have been investigated. The spectra have been modeled with the most recent atomic data using physically relevant parameters only. Good agreement has been found both in modeling the experimental spectra and in the determination of the plasma parameters, such as ion temperature and plasma motion and electron temperature. The deviations between the theoretical and experimental spectra are below 7% for all lines; the precision of the plasma parameters obtained by X-ray spectroscopy agrees with the accuracy of the standard diagnostics at TEXTOR.In addition, the abundance of Li-/He-like ions, as well as the H-/He-like ions, has been measured. For the higher densities, the abundance approaches the coronal expectation. Larger deviations to the coronal limit have been found with neutral beam injection. The system is now being upgraded for spatial resolution.