ANS is committed to advancing, fostering, and promoting the development and application of nuclear sciences and technologies to benefit society.
Explore the many uses for nuclear science and its impact on energy, the environment, healthcare, food, and more.
Explore membership for yourself or for your organization.
Conference Spotlight
2025 ANS Winter Conference & Expo
November 9–12, 2025
Washington, DC|Washington Hilton
Standards Program
The Standards Committee is responsible for the development and maintenance of voluntary consensus standards that address the design, analysis, and operation of components, systems, and facilities related to the application of nuclear science and technology. Find out What’s New, check out the Standards Store, or Get Involved today!
Latest Magazine Issues
Sep 2025
Jan 2025
Latest Journal Issues
Nuclear Science and Engineering
October 2025
Nuclear Technology
September 2025
Fusion Science and Technology
Latest News
PR: American Nuclear Society welcomes Senate confirmation of Ted Garrish as the DOE’s nuclear energy secretary
Washington, D.C. — The American Nuclear Society (ANS) applauds the U.S. Senate's confirmation of Theodore “Ted” Garrish as Assistant Secretary for Nuclear Energy at the U.S. Department of Energy (DOE).
“On behalf of over 11,000 professionals in the fields of nuclear science and technology, the American Nuclear Society congratulates Mr. Garrish on being confirmed by the Senate to once again lead the DOE Office of Nuclear Energy,” said ANS President H.M. "Hash" Hashemian.
L. Esteban, M. Sánchez, J. Sánchez, P. Kornejew, M. Hirsch, J. A. López, A. Fernández, O. Nieto-Taladriz
Fusion Science and Technology | Volume 58 | Number 3 | November 2010 | Pages 771-777
Selected Paper from Sixth Fusion Data Validation Workshop 2010 (Part 2) | doi.org/10.13182/FST10-9
Articles are hosted by Taylor and Francis Online.
Interferometry is used for measuring line average electronic densities in fusion plasmas. The W7-X stellarator will employ a two-color CO2 (10.591 m) and CO (5.295 m) heterodyne-infrared interferometer as an electronic density measurement diagnostic. The frequency displacement is 40 MHz for the CO2 wavelength and 25 MHz for the CO, so these values will fix the heterodyne frequencies. Because the frequency gap between the two carriers is wide enough and the detector sensitivity is similar for both wavelengths, it is possible to use a single detector for the two signals; nevertheless, they should be split with filters. Traditionally, the intermediate-frequency signals should be filtered, downconverted to a lower frequency by the use of analog circuitry, and then processed. A new approach is proposed. The intermediate-frequency signals are directly sampled by means of high-speed analog-to-digital converters followed by a digital diplexer and a specific phase-meter processor implemented in a field-programmable gate array. Preliminary results from the W7-X infrared interferometer prototype, without plasma, are presented.