ANS is committed to advancing, fostering, and promoting the development and application of nuclear sciences and technologies to benefit society.
Explore the many uses for nuclear science and its impact on energy, the environment, healthcare, food, and more.
Explore membership for yourself or for your organization.
Conference Spotlight
2026 ANS Annual Conference
May 31–June 3, 2026
Denver, CO|Sheraton Denver
Standards Program
The Standards Committee is responsible for the development and maintenance of voluntary consensus standards that address the design, analysis, and operation of components, systems, and facilities related to the application of nuclear science and technology. Find out What’s New, check out the Standards Store, or Get Involved today!
Latest Magazine Issues
Dec 2025
Jul 2025
Latest Journal Issues
Nuclear Science and Engineering
January 2026
Nuclear Technology
December 2025
Fusion Science and Technology
November 2025
Latest News
Christmas Light
’Twas the night before Christmas when all through the house
No electrons were flowing through even my mouse.
All devices were plugged by the chimney with care
With the hope that St. Nikola Tesla would share.
Larry G. Blackwood, Yale D. Harker
Nuclear Technology | Volume 138 | Number 1 | April 2002 | Pages 58-68
Technical Paper | Radioactive Waste Management and Disposal | doi.org/10.13182/NT02-A3277
Articles are hosted by Taylor and Francis Online.
Assessment of active mode measurement uncertainty in passive-active neutron radioassay systems used to measure Pu content in nuclear waste is severely hampered by lack of knowledge of the waste Pu particle size distribution, which is a major factor in determining bias in active mode measurements. The sensitivity of active mode measurements to particle size precludes using simulations or surrogate waste forms to estimate uncertainty in active mode measurements when the particle size distribution is not precisely known or inadequately reproduced. An alternative approach is based on a statistical comparison of active and passive mode results in the mass range for which both active and passive mode analyses produce useable measurements. Because passive mode measurements are not particularly sensitive to particle size effects, their uncertainty can be more easily assessed. Once bias corrected, passive mode measurements can serve as confirmatory measurements for the estimation of active mode bias. Further statistical analysis of the errors in measurements leads to precision estimates for the active mode.