ANS is committed to advancing, fostering, and promoting the development and application of nuclear sciences and technologies to benefit society.
Explore the many uses for nuclear science and its impact on energy, the environment, healthcare, food, and more.
Division Spotlight
Mathematics & Computation
Division members promote the advancement of mathematical and computational methods for solving problems arising in all disciplines encompassed by the Society. They place particular emphasis on numerical techniques for efficient computer applications to aid in the dissemination, integration, and proper use of computer codes, including preparation of computational benchmark and development of standards for computing practices, and to encourage the development on new computer codes and broaden their use.
Meeting Spotlight
2024 ANS Annual Conference
June 16–19, 2024
Las Vegas, NV|Mandalay Bay Resort and Casino
Standards Program
The Standards Committee is responsible for the development and maintenance of voluntary consensus standards that address the design, analysis, and operation of components, systems, and facilities related to the application of nuclear science and technology. Find out What’s New, check out the Standards Store, or Get Involved today!
Latest Magazine Issues
Apr 2024
Jan 2024
Latest Journal Issues
Nuclear Science and Engineering
May 2024
Nuclear Technology
Fusion Science and Technology
Latest News
IAEA calls for action following drone attacks at Ukraine nuclear plant
A recent drone attack at Ukraine’s Zaporizhzhia nuclear power plant prompted an emergency meeting by the International Atomic Energy Agency Board of Governors, during which the agency again called for the immediate removal of Russian military and personnel from the site.
J. E. Klein, E. G. Estochen, K. L. Shanahan, L. K. Heung
Fusion Science and Technology | Volume 60 | Number 3 | October 2011 | Pages 914-917
Tritium Storage | Proceedings of the Ninth International Conference on Tritium Science and Technology | doi.org/10.13182/FST11-A12565
Articles are hosted by Taylor and Francis Online.
The Savannah River Site (SRS) tritium facilities have used 1st generation (Gen1) metal hydride storage bed assemblies with process vessels (PVs) fabricated from 3 inch nominal pipe size (NPS) pipe to hold up to 12.6 kg of LaNi4.25Al0.75 metal hydride for tritium gas absorption, storage, and desorption for over 15 years. The 2nd generation (Gen2) of the bed design used the same NPS for the PV, but the added internal components produced a bed nominally 1.2 m long, and presented a significant challenge for heater cartridge replacement in a footprint limited glove-box.A prototype 3rd generation (Gen3) metal hydride storage bed has been designed and fabricated as a replacement candidate for the Gen2 storage bed. The prototype Gen3 bed uses a PV pipe diameter of 4 inch NPS so the bed length can be reduced below 0.7 m to facilitate heater cartridge replacement. For the Gen3 prototype bed, modeling results show increased absorption rates when using hydrides with lower absorption pressures. To improve absorption performance compared to the Gen2 beds, a LaNi4.15Al0.85 material was procured and processed to obtain the desired pressure-composition-temperature (PCT) properties. Other bed design improvements are also presented.