American Nuclear Society
Home

Home / Store / Journals / Electronic Articles / Fusion Science and Technology / Volume 64 / Number 2 / Pages 340-344

MELCOR Accident Analysis for ARIES-ACT

Paul W. Humrickhouse, Brad J. Merrill

Fusion Science and Technology / Volume 64 / Number 2 / Pages 340-344

August 2013

Format:

Price:$30.00
Member Price:$27.00
Member Savings:$3.00

We model a loss of flow accident (LOFA) in the ARIES-ACT1 tokamak design. ARIES-ACT1 features an advanced SiC blanket with LiPb as coolant and breeder, a helium cooled steel structural ring and tungsten divertors, a thin-walled, helium cooled vacuum vessel, and a room temperature water-cooled shield outside the vacuum vessel. The water heat transfer system is designed to remove heat by natural circulation during a LOFA. The MELCOR model uses time-dependent decay heats for each component determined by 1-D modeling. The MELCOR model shows that, despite periodic boiling of the water coolant, that structures are kept adequately cool by the passive safety system.

 
 
 
Questions or comments about the site? Contact the ANS Webmaster.