Numerical Analysis of MHD Flow in a Poloidal Channel of the Chinese DFLL-TBM with a Flow Channel Insert

Hongli Chen, Tao Zhou, Zi Meng, Yican Wu, FDS Team

Fusion Science and Technology / Volume 62 / Number 1 / Pages 157-163

July 2012

Format:

Price:$30.00
Member Price:$27.00
Member Savings:$3.00

A Chinese dual-functional lithium lead test blanket module was proposed for testing in ITER. The flow channel insert (FCI) was inserted in LiPb flow channels to reduce magnetohydrodynamic (MHD) effects and to increase the outlet temperature of coolant LiPb. The FCI has a big influence on the LiPb flow characteristics under the high magnetic field. In this paper, the LiPb MHD flow characteristics both in the gap between the FCI and the channel wall and inside the FCI was numerically calculated using an MHD code named MTC-H 2.0 in a poloidal channel. The influence of the FCI on flow distribution was analyzed. The pressure drop was compared to the case without the FCI, and the pressure equalization was assessed for both sides of the FCI with pressure equalization openings. The impact of electrical conductivity of the FCI material was analyzed.

 
 
 