ANS American Nuclear Society
ANS
ANS HomeAboutMembersJoinContactSearch
Journals

Content

Publications
ANS > Publications > Journals > Nuclear Technology > Volume 121
Thermal-Hydraulic Analysis of Core Shroud Crack for Chinshan BWR/4 Unit 2 Using RETRAN-02/MOD5

Volume 121 · Number 3 · March 1998 · Pages 324-336
Technical Paper · RETRAN

Jan-Ru Tang, Lainsu Kao, Der-Yeong Shiau, Lin-Yao Chou, Ching-Chuan Yao, Show-Chyuan Chiang

ANS Store:  Purchase Article

The RETRAN analyses of three areas of thermal-hydraulic concerns are presented. The first evaluated whether a 360-deg through-wall crack could be detected based on system response with leakage through the crack. The second analysis was to identify the hydraulic load on the shroud and possible consequences early in the main steam-line break. The last was the evaluation of the thermal limit (CPR) of limiting transients with leakage. Some of the analyses were used for justification of continued operation of the current cycle, and some will be useful in the evaluation of the repair design.

<< Return to Volume 121
Questions or comments about the American Nuclear Society web site?  Contact the ANS Webmaster.