ANS is committed to advancing, fostering, and promoting the development and application of nuclear sciences and technologies to benefit society.
Explore the many uses for nuclear science and its impact on energy, the environment, healthcare, food, and more.
Explore membership for yourself or for your organization.
Conference Spotlight
2026 Nuclear Energy Conference & Expo (NECX)
August 24–27, 2026
Dallas, TX|Hilton Anatole
Latest Magazine Issues
Jun 2026
Jan 2026
2026
Latest Journal Issues
Nuclear Science and Engineering
July 2026
Nuclear Technology
June 2026
Fusion Science and Technology
May 2026
Latest News
Spent fuel recycling and conditioning topic of U.S.-Japan meeting
Officials with the Department of Energy’s Office of Environmental Management discussed spent nuclear fuel recycling and conditioning with counterparts from Japan during the 13th U.S.-Japan Technical Meeting of the Civil Nuclear Energy Research and Development Working Group, held recently in Santa Fe, N.M.
Alain Godot, Sébastien Colas, Jean-Charles Hubinois
Fusion Science and Technology | Volume 54 | Number 1 | July 2008 | Pages 186-188
Technical Paper | Tritium Measurement | doi.org/10.13182/FST08-A1792
Articles are hosted by Taylor and Francis Online.
The measurement of the amount of impurities in tritiated gases can be achieved by means of mass spectrometry or gas phase chromatography.A growing number of disadvantages associated to the "life expectancy" of the mass spectrometer and its tricky maintenance (when enclosed in a gloves box) have led us to acquire a micro gas phase chromatograph. This device is based on a modular concept with the injector, the column and the detector packed in a compact unit which is easy to replace. Thanks to constant improvement in the field of capillary column, new micro chromatographs are now able to perform measurement in absence of pre-column and presence of argon instead of nitrogen as a carrier gas. Of importance, this new apparatus allow better performances (running time: 1 m 30 sec, limit of detection: < 10 ppm).However, in normal use, this apparatus requires 800 millibar in the inlet, a pressure that doesn't match with the feature of our process gas. To overcome this inconvenience, we have developed an automatic functioning system with a bellows that samples and compresses the gas to pressures compatible with the micro gas chromatograph.The apparatus and the experimental procedures will be presented as well as experimental performances (reproducibility, detection limits. . .) for some impurities such as nitrogen, oxygen and helium.