ANS is committed to advancing, fostering, and promoting the development and application of nuclear sciences and technologies to benefit society.
Explore the many uses for nuclear science and its impact on energy, the environment, healthcare, food, and more.
Division Spotlight
Robotics & Remote Systems
The Mission of the Robotics and Remote Systems Division is to promote the development and application of immersive simulation, robotics, and remote systems for hazardous environments for the purpose of reducing hazardous exposure to individuals, reducing environmental hazards and reducing the cost of performing work.
Meeting Spotlight
2024 ANS Annual Conference
June 16–19, 2024
Las Vegas, NV|Mandalay Bay Resort and Casino
Standards Program
The Standards Committee is responsible for the development and maintenance of voluntary consensus standards that address the design, analysis, and operation of components, systems, and facilities related to the application of nuclear science and technology. Find out What’s New, check out the Standards Store, or Get Involved today!
Latest Magazine Issues
Mar 2024
Jan 2024
Latest Journal Issues
Nuclear Science and Engineering
April 2024
Nuclear Technology
Fusion Science and Technology
February 2024
Latest News
Can hydrogen be the transportation fuel in an otherwise nuclear economy?
Let’s face it: The global economy should be powered primarily by nuclear power. And it probably will by the end of this century, with a still-significant assist from renewables and hydro. Once nuclear systems are dominant, the costs come down to where gas is now; and when carbon emissions are reduced to a small portion of their present state, it will become obvious that most other sources are only good in niche settings. I mean, why use small modular reactors to load-follow when they can just produce that power instead of buffering it?
D. Testa, M. Toussaint, R. Chavan, A. Encheva, J. B. Lister, J-M. Moret, F. Sanchez
Fusion Science and Technology | Volume 61 | Number 1 | January 2012 | Pages 19-50
Technical Paper | doi.org/10.13182/FST12-A13337
Articles are hosted by Taylor and Francis Online.
The high-frequency (HF) magnetic sensors for ITER are currently based on a conventional, Mirnov-type pickup coil, with an effective area in the range 0.03 < (NA)EFF (m2) < 0.1; the sensor is required to provide measurements of magnetic instabilities with magnitude around [vertical bar]B/B[vertical bar] [approximately] 10-4 in the 10-kHz to 2-MHz frequency range. The physical, mechanical, and electrical properties of one representative ITER HF pickup coil design have been analyzed with particular attention to the manufacturing and assembly process for the winding pack, as its integrity was found to be of concern when performing a coupled electromagnetic, structural, and thermal analysis of the sensor. Three different options for the guiding grooves in that design have been tested, using copper and tungsten for the winding pack, but none of them has been convincing enough due to the likelihood of breakages of the thin grooving and of the tungsten wire itself. Hence, alternative designs still based on a conventional Mirnov-type pickup coil have been explored, and a nonconventional Mirnov-type pickup coil was produced using direct laser cutting of a Type 316 stainless steel hollow tube, avoiding the difficulties encountered during the winding operations for conventional Mirnov-type sensors. This process of manufacturing appears to be acceptable for HF magnetic sensors of Mirnov-type design in ITER, and it is recommended for future prototyping studies, as the effective area of our first prototype, (NA)EFF [approximately] 0.01 m2 , was well below the ITER requirement. The electrical characteristics and the frequency response of all these prototypes were evaluated up to 8 MHz, with the results in good agreement with model calculations. The conventional Mirnov-type prototypes behave as expected in terms of their main electrical properties and should satisfy the present measurement performance requirements. Finally, a direct measurement of the effective area of these sensors has shown that the geometrical value is a sufficiently correct estimate of its actual value at low frequencies (<10 kHz) when the winding pack closely follows the nominal shape of the coil itself.