ANS is committed to advancing, fostering, and promoting the development and application of nuclear sciences and technologies to benefit society.
Explore the many uses for nuclear science and its impact on energy, the environment, healthcare, food, and more.
Division Spotlight
Mathematics & Computation
Division members promote the advancement of mathematical and computational methods for solving problems arising in all disciplines encompassed by the Society. They place particular emphasis on numerical techniques for efficient computer applications to aid in the dissemination, integration, and proper use of computer codes, including preparation of computational benchmark and development of standards for computing practices, and to encourage the development on new computer codes and broaden their use.
Meeting Spotlight
2024 ANS Annual Conference
June 16–19, 2024
Las Vegas, NV|Mandalay Bay Resort and Casino
Standards Program
The Standards Committee is responsible for the development and maintenance of voluntary consensus standards that address the design, analysis, and operation of components, systems, and facilities related to the application of nuclear science and technology. Find out What’s New, check out the Standards Store, or Get Involved today!
Latest Magazine Issues
Apr 2024
Jan 2024
Latest Journal Issues
Nuclear Science and Engineering
May 2024
Nuclear Technology
Fusion Science and Technology
Latest News
College students help develop waste-measuring device at Hanford
A partnership between Washington River Protection Solutions (WRPS) and Washington State University has resulted in the development of a device to measure radioactive and chemical tank waste at the Hanford Site. WRPS is the contractor at Hanford for the Department of Energy’s Office of Environmental Management.
Asad Majid
Fusion Science and Technology | Volume 37 | Number 2 | March 2000 | Pages 103-109
Technical Paper | doi.org/10.13182/FST00-A126
Articles are hosted by Taylor and Francis Online.
Heat transfer to liquid lithium in the presence of a transverse magnetic field and a gravity field was analyzed in a square cross-section duct. The duct had conducting vanadium walls. Magnetohydrodynamic equations in three dimensions in the Cartesian coordinate system were solved. First, the Nusselt number was calculated with no magnetic field and a gravity field. Second, the Nusselt number was calculated for the case of a transverse magnetic field acting on the fluid. Third, the Nusselt number was calculated for the case of a transverse magnetic field and a gravity field acting on the fluid. Only one face of the channel was heated. It was found that the Nusselt number is not sensitive to application of a gravity field and is sensitive to application of a transverse magnetic field and it decreases when a transverse magnetic field is applied. It is observed that when the intensity of the transverse magnetic field reaches 0.11 T, further reduction in the value of the Nusselt number almost stops.